So Mattamy wants to charge me 110 to put in an additional phone jack. Am I correct in thinking that this guy can do it a lot cheaper? Only problem is I dont move till next March so hopefully I wont lose his info.


Top
  
Reply with quote  
 Post subject:
PostPosted: Tue Apr 24, 2007 6:40 pm 
Offline

Joined: Mon Sep 19, 2005 12:42 pm
Posts: 841
Where do you need the jack?


Top
 Profile  
Reply with quote  
 Post subject:
PostPosted: Tue Apr 24, 2007 7:20 pm 
haven't thought that far ahead yet but I'll want more than one. Thinking an extra 2-3.


Top
  
Reply with quote  
 Post subject:
PostPosted: Tue Apr 24, 2007 7:36 pm 
Offline
User avatar

Joined: Wed Jul 21, 2004 7:49 am
Posts: 1850
Location: Your Custom Electronics Installer
Adding extras are relatively cheap. I add quite a bit of extras to Mattamy houses and know them quite well.

_________________
Professional - Audio - Video - Data - Security - Central Vac - Insured - Trained - Certified
http://www.phand.ca/


Top
 Profile  
Reply with quote  
 Post subject: Re: Phone jacks
PostPosted: Mon Apr 30, 2007 12:55 pm 
Offline

Joined: Mon Sep 19, 2005 12:42 pm
Posts: 841
JCD Services wrote:
you must adhere to the proper bend radius or it will be the same at the CAT3 that is being installed in most of your homes


Do you really think radius is an issue for Cat5e? As long as you don't tie the cable in a knot or pinch it you shouldn't have an issue.


Top
 Profile  
Reply with quote  
 Post subject: Re: Phone jacks
PostPosted: Mon Apr 30, 2007 6:11 pm 
Offline
User avatar

Joined: Wed Jul 21, 2004 7:49 am
Posts: 1850
Location: Your Custom Electronics Installer
OneWiredMouse wrote:
[
Do you really think radius is an issue for Cat5e? As long as you don't tie the cable in a knot or pinch it you shouldn't have an issue.


To meet TIA standards and to get it certified, you will not want to bend it more than about 4x the radius. To get all cabling to a certified state is NOT a cheap option and it's rarely done outside of high-end commercial or datacentres.

As for cat5e being replaced by cat6, I disagree. It's still at least 50% more in cost compared to 5e. The majority of CE devices that require wiring are also using cat5e as their spec cable. This includes products from Russound, Colorado vNet, Control 4, Proficient Audio, etc..

cat5e is used for more than just networking.

_________________
Professional - Audio - Video - Data - Security - Central Vac - Insured - Trained - Certified
http://www.phand.ca/


Top
 Profile  
Reply with quote  
 Post subject:
PostPosted: Thu May 03, 2007 9:22 am 
Offline

Joined: Mon Sep 19, 2005 12:42 pm
Posts: 841
Mattamy will do it for you. But you will pay big $$$ for it. I have installed structured cable in several Mattamy homes over the past couple of years prior to the drywall going up. If you contact your "builder" (the person in charge of your house) they will usually allow you to go in and do it yourself. When you ask just specify that you will be running low voltage cable.


Top
 Profile  
Reply with quote  
 Post subject:
PostPosted: Thu May 03, 2007 10:07 am 
Offline

Joined: Mon Sep 19, 2005 12:42 pm
Posts: 841
I believe a conduit from the basement to the attic is reasonable in price. Around $200.


Top
 Profile  
Reply with quote  
 Post subject:
PostPosted: Thu May 03, 2007 10:55 am 
Offline
User avatar

Joined: Wed Jul 21, 2004 7:49 am
Posts: 1850
Location: Your Custom Electronics Installer
TechMonkey wrote:
I suppose an alternative would also be to just have them run conduits everywhere, so you can easily run whatever you need later. I suppose they would charge big $$$ for that too. :(


Ultimately you would want to run smurf tube to every room and home run it, but that is a huge job because it requires a lot of drilling of big holes.

_________________
Professional - Audio - Video - Data - Security - Central Vac - Insured - Trained - Certified
http://www.phand.ca/


Top
 Profile  
Reply with quote  
 Post subject: Great Service
PostPosted: Wed Jun 06, 2007 11:55 pm 
Offline

Joined: Wed Jun 06, 2007 1:48 pm
Posts: 87
Denny, thank you for installing our D/W. Very neat and clean installation.


Last edited by NewInMilton on Thu Jan 03, 2008 10:08 pm, edited 1 time in total.

Top
 Profile  
Reply with quote  
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 10 posts ] 

All times are UTC - 5 hours


Who is online

Users browsing this forum: No registered users and 19 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
Powered by phpBB® Forum Software © phpBB Group
[ Time : 0.017s | 11 Queries | GZIP : Off ]